Dual Energy X-ray Absorptiometry Bone Densitometer MSLBD11

Dual Energy X-ray Absorptiometry Bone Densitometer MSLBD11 adopts the Full Closed Lead Protective Window to Measure, only Need to Put the Patient’s Arm into the Window. The Equipment is indirect contact with the scanning parts of the patient and is easy to operate for the doctor. It is safe for the patient and doctor.

Description

Features of Ultrasound Bone Sonometer MSLBD10

  • Suitable for all kinds of medical and physical examination institutions
  • Light and portable: The product appearance is small and elegant, easy to carry, can link desktop computer, laptop or tablet.
  • Convenient: Measurement position is radius (or tibia), it is very convenient and easy to use.
  • Reliable Result : The measurement results are not affected by soft tissue thickness, bone size, and skeletal shape.
  • Wide applicability: Including Asia, Europe and other region database, multi-age data can be chosen

Specification of Ultrasound Bone Sonometer MSLBD10

  • The center working frequency of the ultrasonic probe; the broadband probe has a frequency of 1.00 MHz, the error range is ±15%, and the actual test result is within ±4%. More penetrating power, accurate measurement, and adapt to people of different ages.
  • Bone sound velocity (SOS) measurement range; 2100-4800m/s
  • Randomly provide calibration module test, USB connection PC interface, plug and play, convenient and flexible;
  • Ultrasonic speed SOS measurement accuracy ≤ ± 1.5%, the actual test results are within ≤ 0.36%,
  • Ultrasonic speed SOS test accuracy ≤ ± 0.4%, the actual test results are within ≤ 0.18%,
  • Ultrasonic speed SOS test repeatability ≤ 0.15%, the actual test results are within ≤ 0.10%;
  • Measurement range; children (0-20 years old), adults/old people (20-100 years old), fully automated analysis to obtain results;
  • Single point measurement: <1 second; single measurement ≤ 25 seconds; repeated accurate measurement ≤ 75 seconds; complete fastness detection;
  • Multi-ethnic and Asian ethnic (China) normal reference database (curve template) and statistical functions support multi-language, software language switchable
  • Completion parameters are complete:
    • Adult: T value, Z value, age ratio, adult ratio, physiological age of the bone (PAB), age at which osteoporosis is expected (EOA), relative fracture risk (RRF), bone strength index (BQI)
    • Children: Z value, physiological age of the bone (PAB), height prediction, obesity, BMI index